heidenhain PWT 100, PWT 101 — 8.5.3 Encoder information screen

8 Encoder diagnostics | Diagnostics for encoders with 1 V PP /11 µA PP /1 V PP + Z1 interface AB-CD deviation In the bar graph of the AB-CD deviation, the position of the black bar indicates the deviation of the calculated Z1-track position. The reference to the corresponding reference position is made on the basis of the C and D signals. The reference position is established from the incremental track, based on the A and B signals. The farther the black bar moves away from the center position, the larger the deviation from the reference position is. Figure 28: AB-CD deviation (distance between graduation lines:

1°, with one encoder revolution corresponding to 360°) 8.5.3 Encoder information screen Figure 29: Encoder information screen The Encoder information screen displays information saved about the connected encoder. Precondition: The encoder supports this function. The Encoder information screen displays only selected information on the connected encoder. This screen does not show the complete memory contents of the encoder. HEIDENHAIN | PWT 100, PWT 101 | Operating Instructions | 07/2024 85