Encoder diagnostics | Diagnostics for encoders with 1 V PP /11 µA PP /1 V PP + Z1 interface 8 8.5.2 Sine commutation (1 V PP + Z1) screen Figure 26: Sine commutation screen The Sine commutation screen uses bar graphs to evaluate the commutation signal of encoders with 1 V PP + Z1 interface. The following information about the encoders is shown: Sig.Amp. Signal amplitude Sig.Dev. Signal deviation CD.Amp. Commutation signal CD AB-CD Deviation of AB and CD The bar graphs for the display of the signal amplitude and signal deviation correspond to the bar graphs in the PWT display screen. Further information:
"PWT display screen ", Page 78 The commutation signals C and D are taken from the so-called Z1 track, and are equal to one sine or cosine period per revolution. They have a signal amplitude of typically 1 V PP . Commutation signal CD In the bar graph of the CD amplitude, the position of the black bar indicates the commutation signal. The farther the black bar moves to the right, the larger the value of the amplitude is. Figure 27: CD amplitude 1 V PP (distance between graduation lines: 0.1 V PP ) 84 HEIDENHAIN | PWT 100, PWT 101 | Operating Instructions | 07/2024