8 Encoder diagnostics | Diagnostics for encoders with 1 V PP /11 µA PP /1 V PP + Z1 interface 8.5.5 Switching signals screen 1 3 2 5 4 Figure 31: Switching signals screen 1 Signal level of the switching signal: gray (low) / green (high) 2 Rising edge 3 Locking function 4 No value determined 5 Falling edge On the Switching signals screen, the proper functioning of switching signals, e.g. homing and limit signals, can be checked. For information on the availability and function of the switching signals, please refer to the encoder documentation or the Interfaces of HEIDENHAIN Encoders brochure. You can evaluate different switching signals.

The possible settings for the different switching signals that can be evaluated are described in the More menu. Further information: "Evaluation options for switching signals ", Page 90 You have to home the encoder to ensure the proper functioning of the display. A corresponding note is displayed upon initial display or after a refresh. Prior to referencing of encoders without distance-coded reference marks: In the Display options for count value screen, select the default value Once Prior to referencing of encoders with distance-coded reference marks: In the Display options for count value screen, select the c-Coded value HEIDENHAIN | PWT 100, PWT 101 | Operating Instructions | 07/2024 87