Encoder diagnostics | Diagnostics for encoders with 1 V PP /11 µA PP /1 V PP + Z1 interface 8 Locking function The Switching signals screen includes a locking function. The locking function enables you to lock or release count values. When you open the "Switching signals" screen for the first time, both padlock icons are shown opened. Updating of the count values is enabled. When two valid signal edges are detected, the padlock icon is closed automatically and the display is frozen. You can change the status by tapping the padlock icon. When you tap the padlock icon for the first time, the automatic operation of the locking function is stopped.
Status Function The display of the count values is frozen The count values are no longer updated Updating of the count values is enabled 8.5.6 More menu You can open the More menu from the following screens of the Diagnosis menus by using the More button: PWT display screen Sine commutation (1 V PP + Z1) screen Counts screen Switching signals screen The More menu provides the following screens: Screen Function Function settings The Function settings screen enables you to switch on/ off special encoder functions. Display options for count value The Display options for count value screen enables you to define display options for the count value.
Analysis information The Analysis information screen shows messages on the signal analysis. Display settings In the Display settings screen, you can define and set the display of the count values. The functions provided by the More menu depend on the respective screens. Opening the More menu Tap More The More menu is opened 88 HEIDENHAIN | PWT 100, PWT 101 | Operating Instructions | 07/2024