Industrial — CODE 42 XX — SHORT-TO-BATTERY IN SOLENOID CIRCUIT

WTEC III ELECTRONIC CONTROLS TROUBLESHOOTING MANUAL CODE 42 XX — SHORT-TO-BATTERY IN SOLENOID CIRCUIT 6–60 Copyright © 2001 General Motors Corp.

TRANSMISSION FEEDTHROUGH SOLENOID HARNESS CONNECTOR CONNECTOR GRAY ECU B A “T” CONNECTOR N (BLUE) BLACK BLU E Y A T16 D BLU E T32 T17 T1 TRANSMISSION 195–T13 YELLOW ECU SEE NOTE W T13 TRANSID 120–T4 WHITE G T4 A SOL A A 42 12 B TID 2 102–T1 ORANGE SOLENOID A, D, J A T1 POWER 131–T21 BLUE M T21 D SOL D A 42 15 B TID 5 111–T8 GREEN e T8 J SOL **J 42 24 SEE NOTE 128–T20 ORANGE J T20 B SOL B A 42 13 B TID 3 H 121–T2 TAN T2 SOLENOID B, E A HI POWER 129–T6 TAN K T6 E SOL E A 42 16 B TID 6 SEE NOTE 103–T5 GREEN B T5 C SOL C A 42 14 B TID 4 130–T17 YELLOW SOLENOID C, G L T17 POWER 104–T7 WHITE C T7 G SOL G A 42 22 B TID 7 SEE NOTE 107–T3 GREEN E T3 F SOL POWER F A 42 21 B 110–T22 WHITE F T22 F SOL TID 8 116*–T19 YELLOW g T19 SOLENOID H, N POWER **N A 42 26 B 101–T24 BLUE f T24 N SOL RTDR ACCUMULATOR 101–T24 BLUE A N A 42 26 B 116*–T19 YELLOW B Future use RTDR OR DIFFERENTIAL SEE NOTE See Appendix D For LOCK (T–CASE) Detailed Terminal Location.

127–T23 WHITE A T23 H SOL H A 42 23 B 116*–T19 YELLOW B *Wire designation may include a letter suffix which indicates NOTE: These wires may pass through a bulkhead connector. a splice to the same number wire. See wiring schematic in **Only present in sump on MD 3070 and HD 4070 models. Appendix J for more detail on splice letter designations. V070 89 Figure 6–14. Code 42 Schematic Drawing A B A B A B