WTEC III ELECTRONIC CONTROLS TROUBLESHOOTING MANUAL CODE 44 XX — SHORT-TO-GROUND IN SOLENOID CIRCUIT (Figure 6–16) Main code 44 indicates the ECU has detected a short-to-ground in a solenoid or its wiring. The DO NOT SHIFT response is activated when some subcodes are detected, all solenoids are turned off, and the CHECK TRANS light is illuminated. NOTE: Code 44 XX may be caused by a short-to-ground of wire 195 (TransID). NOTE: For subcodes 12, 13, 14, 15, 16, 22 — neutral start is inoperable. Subcodes 21, 23, 24, and 26 do not trigger the CHECK TRANS light. A. Active Indicator Clearing Procedure: Power down Manual NOTE:
Intermittent connections or lack of battery-direct power and ground connections may cause this and other codes. NOTE: Before troubleshooting, read Paragraph 6–6. Also, check battery and ECU input voltages. PROBING THE CONNECTOR When testing the control module solenoids from the feedthrough connector with the internal harness connected, the resistance of each solenoid can be checked using a VOM. Refer to Figure 6–17 for resistance values versus temperature. Copyright © 2001 General Motors Corp.
6–65 Main Code Subcode Meaning 44 12 Short-to-ground A Solenoid Circuit 44 13 Short-to-ground B Solenoid Circuit 44 14 Short-to-ground C Solenoid Circuit 44 15 Short-to-ground D Solenoid Circuit 44 16 Short-to-ground E Solenoid Circuit 44 21 Short-to-ground F Solenoid Circuit 44 22 Short-to-ground G Solenoid Circuit 44 23 Short-to-ground H Solenoid Circuit 44 24 Short-to-ground J Solenoid Circuit 44 26 Short-to-ground N Solenoid Circuit