Industrial — CODE 45 XX — OPEN CONDITION IN SOLENOID CIRCUIT

WTEC III ELECTRONIC CONTROLS TROUBLESHOOTING MANUAL CODE 45 XX — OPEN CONDITION IN SOLENOID CIRCUIT TRANSMISSION FEEDTHROUGH HARNESS CONNECTOR SOLENOID CONNECTOR BLACK GRAY ECU Y N B A BLUE BLUE ТТУ CONNECTOR (BLUE) D A T16 T32 TRANSMISSION 195–T13 YELLOW ECU T17 T1 W G 120–T4 WHITE T4 SEE NOTE T13 TRANSID A 45 12 TID 2 A 102–T1 ORANGE T1 SOLENOID A, D, J POWER A SOL M 131–T21 BLUE T21 D SOL D 45 15 TID 5 e 111–T8 GREEN T8 ** J 45 24 SEE NOTE J SOL J 128–T20 ORANGE T20 B SOL B 45 13 A B TID 3 H 121–T2 TAN T2 SOLENOID B, E POWER A HI E 45 16 K 129–T6 TAN T6 E SOL TID 6 B 103–T5 GREEN SEE NOTE C 45 14 A B TID 4 L 130–T17 YELLOW T5 SOLENOID C, G POWER C SOL C 104–T7 WHITE T17 T7 G SOL G 45 22 TID 7 SEE NOTE A B F 45 21 E 107–T3 GREEN T3 F SOL POWER F 110–T22 WHITE T22 F SOL A B ** N 45 26 TID 8 g T19 SOLENOID H, N POWER f 101–T24 BLUE T24 N SOL 116 * –T19 YELLOW 101–T24 BLUE RTDR ACCUMULATOR 101–T24 BLUE A B N 45 26 A 116 * –T19 YELLOW Future use B See Appendix D For Detailed Terminal Location.

RTDR OR DIFFERENTIAL LOCK (T PCASE) SEE NOTE H 45 23 A B A 127–T23 WHITE T23 H SOL B * Wire designation may include a letter suffix which indicates a splice to the same number wire. See wiring schematic in Appendix J for more detail on splice letter designations. 116 * –T19 YELLOW NOTE: These wires may pass through a bulkhead connector. ** Only present in sump on MD 3070 and HD 4070 models. V07091 Figure 6–18. Code 45 Schematic Drawing 6–68 Copyright © 2001 General Motors Corp. A B A B A B