Industrial — CODE 46 XX — OVERCURRENT TO SOLENOIDS

WTEC III ELECTRONIC CONTROLS TROUBLESHOOTING MANUAL CODE 46 XX — OVERCURRENT TO SOLENOIDS (Figure 6–20) Main code 46 indicates that an overcurrent condition exists in one of the switches sending power to the transmission control solenoids. A. Active Indicator Clearing Procedure: Power down Manual B. Troubleshooting: 1. Probable cause is a wiring problem. A solenoid wire is probably shorted to ground or the solenoid has a shorted coil which would cause an overcurrent condition. May also be an ECU problem. NOTE: Code 46 XX may be caused by a short-to-ground of wire 195 (TransID). 2. Follow the troubleshooting steps for code 44 XX. Copyright © 2001 General Motors Corp.

6–73 Main Code Subcode Meaning 46 21 Overcurrent, F-High solenoid circuit 46 26 Overcurrent, N and H-High solenoid circuit 46 27 Overcurrent, A-High solenoid circuit