Industrial — CODE 51 XX — OFFGOING RATIO TEST DURING SHIFT (TIE-UP TEST)

WTEC III ELECTRONIC CONTROLS TROUBLESHOOTING MANUAL CODE 51 XX — OFFGOING RATIO TEST DURING SHIFT (TIE-UP TEST) Main code 51 indicates a failed offgoing ratio test. An offgoing ratio test occurs during a shift and uses turbine and output speed sensor readings to calculate the ratio between them. The calculated speed sensor ratio is then compared to the programmed speed sensor ratio of the commanded range. After a shift is commanded, the ECU, after a period of time, expects the old ratio to be gone. If the ratio does not change properly, the ECU assumes the offgoing clutch did not release. The shift is retried if conditions still exist to schedule the shift.

If the second shift is not successfully completed, code 51 XX is set and the ECU returns the transmission to the previous range. Additional codes could be logged for other shifts where “X” indicates the range from and “Y” indicates the range to. NOTE: This test is not performed below a calibrated transmission output speed of 200 rpm. A. Active Indicator Clearing Procedure: Power down Manual — subcodes 01, 10, 12, 21, 23, 24, 46, 64, and 65 NOTE: Before troubleshooting, read Paragraph 6–6. Also, check battery and ECU input voltages. NOTE: Intermittent connections or lack of battery-direct power and ground connections may cause this and other codes. B. Troubleshooting: NOTE:

When a shift completes before the offgoing ratio test completes, an incorrect code 53 12 may be set instead of 51 12. This should be corrected in software versions 9B and later. 1. Incorrect fluid level can cause 51 series codes. Allow the vehicle to idle for 3–4 minutes and check the transmission fluid level. If level is not correct, add or drain fluid to correct level. 6–74 Copyright © 2001 General Motors Corp.

Main Code Subcode Meaning 51 01 Low–1 upshift 51 10 1–Low downshift 51 12 1–2 upshift 51 21 2–1 downshift 51 23 2–3 upshift 51 24 2–4 upshift 51 35 3–5 upshift 51 42 4–2 downshift 51 43 4–3 downshift 51 45 4–5 upshift 51 46 4–6 upshift 51 53 5–3 downshift 51 64 6–4 downshift 51 65 6–5 downshift 51 XY X–Y upshift or downshift