WTEC III ELECTRONIC CONTROLS TROUBLESHOOTING MANUAL APPENDIX E — CONNECTOR PART NUMBERS, TERMINAL PART NUMBERS, TOOL PART NUMBERS, AND REPAIR INSTRUCTIONS Copyright © 2001 General Motors Corp. B. Terminal Removal 1. ECU Harness Connectors (Figure E–1A) CAUTION: The color-code of the strain relief should match the color-code of the retainer. However, cases have been reported where this has not occurred. The retainer color-code and key configuration ensures that the proper wiring harness connector is in the right socket of the ECU. The color- code of the strain relief is of secondary importance and may not agree with the retainer.
Change the strain relief to match the color-code of the retainer (Figure E–1A) when color-code mismatch is found. a. Use a small-bladed screwdriver to gently release the locktabs at the splitline of the strain relief. b. Spread the strain relief open. c. Remove the retainer from the connector by using a small-bladed screwdriver to depress the locktabs on the side of the connector. d. Remove a selected terminal by pushing forward on the wire or by lifting the locking finger and pulling the wire and terminal rearward out of the connector. 2. VIWV and VIWS Harness Connectors and Shift Selector (Device) Connectors (Figure E–1B) a.
Lift locktab on the side of the connector and remove the lock assist. b. Open the conduit clip on the back of the connector after lifting locktabs on each side and sliding clip back to release it from connector. c. Use the J 39227 tool to release the locking finger inside the connector and pull the terminal/wire out the rear of the connector. 3. VIWV and VIWS (Device) Connectors and Shift Selector Harness Connectors (Figure E–1B) a. Carefully insert a small screwdriver blade between the connector body and the secondary lock. Twist/pry to remove the secondary lock from the connector body. b.
Open the conduit clip on the back of the connector after lifting locktabs on each side and sliding clip back to release it from connector. c. Use the J 39227 tool to release the locking finger inside the connector and pull the terminal/wire out the rear of the connector. C. Terminal Crimping 1. Carefully strip insulation to leave 5.0 mm ± 0.5 mm (0.20 ± 0.02 inch) of bare wire showing. 2. Insert the new terminal to be crimped in the J 42215 crimping tool. There is a spring-loaded terminal positioner at the front of the tool to hold the terminal in place. Squeeze the crimper handles for a few clicks to start the crimping process but leave room to insert the wire end. 3.
Insert the bare wire end into the terminal. Squeeze the crimper handles to complete the crimping process and until the crimper handles open when released to remove the terminal/wire from the tool.