WTEC III ELECTRONIC CONTROLS TROUBLESHOOTING MANUAL APPENDIX E — CONNECTOR PART NUMBERS, TERMINAL PART NUMBERS, TOOL PART NUMBERS, AND REPAIR INSTRUCTIONS C. Terminal Crimping (cont’d) 4. Complete terminal installation for VIW and Shift Selector Connectors as follows: (Figure E–1B) a. Insert the wire seal in the back of the connector. b. Push the terminal/wire assembly through the proper hole in the back of the wire seal. Push the wire in until the terminal clicks into position. Gently pull rearward on the wire to be sure that the terminal is fully seated. Install cavity plugs as needed. c. Install the lock assist or secondary lock into the connector body. d.
Close the conduit clip around the conduit and lock the clip into the rear of the connector body. 5. Complete terminal installation of the ECU Connectors as follows: (Figure E–1A) a. Align the locking posts on the connector with the seal and push the locking posts through the seal into the mating holes in the strain relief (if the connector was removed from the strain relief). b. Push the terminal/wire assembly through the proper hole in the back of the seal. Push the wire in until the terminal clicks into position. NOTE: All terminals must be properly positioned to install the retainer in Step (5c). c. Install the retainer on the connector body to lock the terminals in position.
Pull rearward on the wire to be sure that the terminal is fully seated. Install cavity plugs as needed. d. Position the conduit inside the strain relief and snap the strain relief halves together. Copyright © 2001 General Motors Corp.