Industrial — 1–9. DEUTSCH IPD/ECD CONNECTORS (31-WAY BULKHEAD; 31-WAY FEEDTHROUGH HARNESS; 16-WAY OPTIONAL SEN...

WTEC III ELECTRONIC CONTROLS TROUBLESHOOTING MANUAL APPENDIX E — CONNECTOR PART NUMBERS, TERMINAL PART NUMBERS, TOOL PART NUMBERS, AND REPAIR INSTRUCTIONS Use Description Manufacturers P/N 16-Way Optional Sensor Harness 16-Way Plug Terminal (Socket) Cavity Plug Backshell Housing Backshell Follower Backshell Grommet 16-Way Receptacle Terminal (Pin) Cavity Plug Panel Nut O-Ring Seal Lockwasher Backshell Housing Backshell Follower Backshell Grommet WT06B20-16SN 3662-204-1690 0613-1-1601 WTA10-20-01/16 WTA10-20-02/16 WTA10-20-03 WT04B20-16PN 3660-201-1690 0613-1-1601 0926-207-2087 9013-3-0201 9014-212-2086 WTA10-20-01/16 WTA10-20-02/16 WTA10-20-03 6-Way Optional DDR 6-Way Plug Terminal (Pin) Terminal (Pin) Cavity Plug Backshell Cover HD10-6-12P 0460-256-12233 0460-204-0831 114017 HD18-006 HDC16-6 9-Way Optional DDR 9-Way Receptacle HD10-9-1939P NOTE:

If difficulty is encountered in removing or installing the plug backshell, insert the plug into the receptacle, do not lock it into place, and loosen the backshell. B. Terminal Removal (Refer to Figure E–10, View A) NOTE: When using remover/inserter tool J 41194, take care not to break the tip of the tool. Lay the wire in the widest part of the wire slot and work toward the tool tip. 1. Loosen and slide the backshell along the convolute conduit. 2. Remove the convolute conduit from the base of the backshell follower. Peel enough conduit from the harness to allow working access. 3. Slide the backshell follower clear of the connector housing. 4.

Remove as much tape wrap as necessary to allow working access. 5. Fully insert the proper remover/extractor tool into the back of the connector until it releases the ter- minal. 6. Pull the terminal, wire, and tool out the back of the connector. 7. If replacing the terminal, cut the wire through the middle of the terminal crimp (this minimizes wire loss). C. Terminal Crimping (Refer to Figure E–10, View B) 1. Strip approximately 6–8 mm (0.236–0.315 inch) of insulation from the wire. 2. Set the crimping tool wire size to number 18 for the ECD or IPD connector. For the optional DDR connector, set the wire size to number 12. To set the wire size, remove the retainer pin.

Lift and ro- tate the indicator until the correct wire number is aligned with the SEL NO. arrow. Reinstall the retainer pin. E–32 Copyright © 2001 General Motors Corp.