WTEC III ELECTRONIC CONTROLS TROUBLESHOOTING MANUAL F. DUAL INPUT AUXILIARY FUNCTION RANGE INHIBIT USES: Prevents inadvertent range selection when auxiliary equipment is operating. Used in emergency equipment to prevent inadvertent range selection from NEUTRAL. VARIABLES TO SPECIFY: None VOCATIONS: Fire trucks, crash trucks WIRE 105 SERVICE INDICATOR SWITCHED POWER WIRE 153 AUX. FUNCTION RANGE INHIBIT INPUT 1 SERVICE TRANS NOTE: Both input signals must turn on within 120 seconds.
If the state of the two input signals is different for longer than this time period, the “SERVICE TRANS” light will be illuminated, a code will be stored in memory, and neutral-to- range shifts will NOT be inhibited. NOTE: The “SERVICE TRANS” light must be mounted in the dash and in clear view of the operator. Preferred lens color is red (amber is acceptable). OPTIONAL CUSTOMER-FURNISHED VIW CONNECTOR(S) WIRE 161 SIGNAL RETURN AUXILIARY FUNCTION SELECT SWITCH 1* ECU WIRE 155 AUX. FUNCTION RANGE INHIBIT INPUT 2 AUXILIARY FUNCTION SENSE SWITCH 2* S WIRE 143 A2 VIM K2 WIRE 343C BATTERY GROUND * Switch is closed when auxiliary equipment is operating.
WIRE 143 A1 K1 WIRE 343A + V04862.01 Figure P–8. Dual Input Auxiliary Function Range Inhibit Copyright © 2001 General Motors Corp. APPENDIX P — INPUT/OUTPUT FUNCTIONS WARNING! WARNING! These schematics show the intended use of the specified controls features which have been validated in the configuration shown. Any miswiring or use of these features which ddiiffffeerrss ffrroomm t thhaatt s hshoowwnn c ocouuldld c arues ue lut ninin dteanmdaegde s etole ecqtiuoinp omf ernatn ogre op r ooptheretry u, npper seodnicatla ibnljeu orpy,e roart il onss r oesf ullitfien. gA iLnL dIaSmOaNg eT tRo AeqNuSipMmISenStI OorN p rISop NerOtyT, pLeIrAsBonLaEl iFnOjuRry ,T oHrE lo CssO oNf SliEfeQ.
AULELNICSEOSN A TSRSAONCSIAMTIESSDI OWNI TISH NMOITS WLIIARBINLGE FOORR U NTIHNTEE NCDOENDS EUQSEU EONFC TEHSE SAES SFOEACTIAUTREEDS . WITH MISWIRING OR UNINTENDED USE OF THESE FEATURES. If current in lamp circuit exceeds 0.5 amp, ground SERVICE TRANS lamp through a relay SWITCHED POWER NC COM NO TRANS V V-19 V-12 V-31 V-11 V-32 V-17