Industrial — APPENDIX P — INPUT/OUTPUT FUNCTIONS

WTEC III ELECTRONIC CONTROLS TROUBLESHOOTING MANUAL G. AUXILIARY HOLD USES: Provide a discrete input to hold the transmission in present range. VARIABLES TO SPECIFY: None VOCATIONS: Various OPTIONAL CUSTOMER-FURNISHED VIW CONNECTOR(S) SEE TABLE A OPTION 1 OPTION 2 TABLE A V SEE TABLE A AUXILIARY HOLD WIRE 161 SIGNAL RETURN MOMENTARY SWITCH V-31 Function is activated when switch is depressed. Function is de-activated when switch is released. ECU S NOTE: Transmission will continue to operate with normal downshift schedule when function is active. V04863.02 Figure P–9. Auxiliary Hold Copyright © 2001 General Motors Corp. APPENDIX P — INPUT/OUTPUT FUNCTIONS WARNING!

These schematics show the intended use of the specified controls features which have been validated in the configuration shown. Any miswiring or use of these features which differs from that shown could result in damage to equipment or property, personal injury, or loss of life. ALLISON TRANSMISSION IS NOT LIABLE FOR THE CONSEQUENCES ASSOCIATED WITH MISWIRING OR UNINTENDED USE OF THESE FEATURES. PIN V-12 WIRE 153 PIN V-14 WIRE 177