WTEC III ELECTRONIC CONTROLS TROUBLESHOOTING MANUAL L. AUTOMATIC NEUTRAL — SINGLE INPUT SWITCHED TO POWER (WIRE 119) USES: Provides for automatic selection of NEUTRAL when PTO is operated regardless of range selected. Requires re-selecting range to shift out of NEUTRAL. Shown with range indicator output. VARIABLES TO SPECIFY: Maximum output speed for activating this function. Range indicator = neutral. VOCATIONS:
Various (with usage of PTO) V-2 WIRE 114 RANGE INDICATOR (Neutral) SWITCHED POWER OPTIONAL CUSTOMER-FURNISHED VIW CONNECTOR(S) V DASH SWITCH DASH LIGHT ECU A2 A3 PTO PRESSURE SWITCH S-18 WIRE 166 RANGE INDICATOR (Neutral) ALTERNATE CONFIGURATION F3 S Relay shown de-energized VIM S-11 WIRE 119 AUTOMATIC NEUTRAL FOR PTO (OPTIONAL) V07118 Figure P–19. Automatic Neutral — Single Input Switched to Power (Wire 119) Copyright © 2001 General Motors Corp. P–19 APPENDIX P — INPUT/OUTPUT FUNCTIONS WARNING! These schematics show the intended use of the specified controls features which have been validated in the configuration shown.
Any miswiring or use of these features which differs from that shown could result in damage to equipment or property, personal injury, or loss of life. ALLISON TRANSMISSION IS NOT LIABLE FOR THE CONSEQUENCES ASSOCIATED WITH MISWIRING OR UNINTENDED USE OF THESE FEATURES. WARNING! If this function is enabled in the shift calibration, the function MUST be integrated into the vehicle wiring. If the function is available in the shift calibration but will not be used in the vehicle, it MUST be disabled in the calibration. This function must not be used with Neutral Indicator For PTO (Output “S”). NC NC COM NO PTO