WTEC III ELECTRONIC CONTROLS TROUBLESHOOTING MANUAL AL. SHIFT SELECTOR TRANSITION AND SECONDARY SHIFT SCHEDULE WITHOUT AUTO NEUTRAL USES: Provides for operator selection of dual shift selectors and shift schedules. Primary mode will always be active when shift selector 1 is selected, and secondary mode will always be active when shift selector 2 is selected. VARIABLES TO SPECIFY: None VOCATIONS: Dual-station refuse vehicles , crane carrier OPTIONAL CUSTOMER-FURNISHED VIW CONNECTOR(S) WIRE 155 SHIFT SELECTOR TRANSITION AND SECONDARY SHIFT SCHEDULE When ECU is turned on, active shift selector is determined by current switch position. V-11 DASH SWITCH Open:
Selector 1 and primary mode shift schedule Closed: Selector 2 and secondary mode shift schedule V V-31 WIRE 161 SIGNAL RETURN SELECTOR 1 SELECTOR 2 ECU Display of the inactive selector is disabled. SELECT SELECT To switch between selector 1 and selector 2, Neutral must be selected and attained, and output speed must be below 60 rpm. S R N MODE R N MODE For Shift Selector wiring requirements, see installation drawing AS07-27 (see SA2978 WTEC III Controls and General Information) D D V04889.01 Figure P–42. Shift Selector Transition and Secondary Shift Schedule Without Auto Neutral Copyright © 2001 General Motors Corp. P–43 APPENDIX P — INPUT/OUTPUT FUNCTIONS WARNING!
These schematics show the intended use of the specified controls features which have been validated in the configuration shown. Any miswiring or use of these features which differs from that shown could result in damage to equipment or property, personal injury, or loss of life. ALLISON TRANSMISSION IS NOT LIABLE FOR THE CONSEQUENCES ASSOCIATED WITH MISWIRING OR UNINTENDED USE OF THESE FEATURES. WARNING! If this function is enabled in the shift calibration, the function MUST be integrated into the vehicle wiring. If the function is available in the shift calibration but will not be used in the vehicle, it MUST be disabled in the calibration.