WTEC III ELECTRONIC CONTROLS TROUBLESHOOTING MANUAL APPENDIX Q — TRANSID 2 THERMISTOR TROUBLESHOOTING INFORMATION Resistance Vs. Temperature Characteristics Graph Q–1 is a graph of the temperature indicated by the resistance measured in the new and the old thermistors. The new thermistors have a negative temperature coefficient which means the indicated temperature increases as the measured resistance decreases within a range of about 200,000 Ohms ( Ω ) down to about 50 Ohms ( Ω ) for the sump thermistor and about 400,000 Ohms ( Ω ) down to about 60 Ohms ( Ω ) for the retarder thermistor.
The old thermistors (sump and retarder) have a positive temperature coefficient which means that the indicated temperature increases as the measured resistance increases within a range from about 500 Ohms ( Ω ) up to about 2500 Ohms ( Ω ). The two thermistors require different ECU calibrations. Mismatches between the ECU and the transmission can cause performance problems or diagnostic codes to be set. This is why the TID 2 transmission is not compatible with the WTEC II ECU (V6E, V7, or V7A) or with the WTEC III ECU (V8).
The proper shift and temperature characteristics for both the TID 1 and the TID 2 transmission are calibrated in the V8A and later WTEC III ECU and the proper calibration will be activated by the ECU according to the TransID wire (wire 195) connection point in the internal harness.
RESISTANCE-TEMPERATURE CHARACTERISTIC CHART 1,000,000 100,000 SENSOR RESISTANCE ( Ω ) 10,000 1,000 100 10 1 ° C 200 170 140 110 80 50 20 ° F 392 338 284 230 176 122 68 14 WTEC III (V8A) Negative Temperature Coefficient Sensor — Retarder TEMPERATURE WTEC III (V8A) Negative Temperature Coefficient Sensor — Sump WTEC II (V6E, V7, and V7A) and WTEC III (V8) Positive Temperature Coefficient Sensor — Sump and Retarder (for comparison only) Graph Q–1. V04711 NOTE: Look carefully at the graph. The scale for the resistance {on the left side} is not constant {linear}. It is logarithmic which means it can display a great range of values within a small space.
Each section of the graph is ten units, but the units vary from 1 to 100,000 Ohms. The range of resistance for the old thermistor is very small when compared with that of the new thermistors. The following table shows the range of resistance values that correspond to either retarder or sump fluid temperature shown in one degree increments over the operating range of the thermistors. Copyright © 2001 General Motors Corp.