WTEC III ELECTRONIC CONTROLS TROUBLESHOOTING MANUAL CODE 13 XX — ECU INPUT VOLTAGE (Figure 6–2) DIAGNOSTIC CODES 6–22 Copyright © 2001 General Motors Corp. 4. If power is correct but the diagnostic tool reading indicates incorrect voltage, closely inspect terminals V1 and V16 or S16; make sure they are not corroded or deformed. Clean or replace as necessary (see Appendix E, Paragraph 1–1). 5. If the voltage condition is intermittent, closely inspect the vehicle wiring for transmission system power and grounds. Check for loose, dirty, or painted connections. Check the VIM for loose, incorrect, or overheating relays or fuses (refer to Appendix G).
Check for wires that are chafed and touching other components. CAUTION: Using an unmatched ECU/CIN combination may result in additional codes being set or in transmission clutch damage. Using an ECU from another vehicle is not a recommended procedure where the test will involve driving the vehicle. This is because the stored adaptive information is tuned to the original vehicle's transmission and those adaptive settings may not perform as expected in another vehicle. Transmission performance could be worse and damage to the clutches may occur. NOTE:
If using an ECU from another vehicle is unavoidable, the ECU must be set to unadapted shifts and the vehicle must be driven carefully to adapt the shifts to the test vehicle. Refer to Service Information Letter 16-WT-96 for the correct procedure. Be sure to reset the ECU to unadapted shifts when it is returned to the original vehicle. 6. If the condition persists, replace the ECU with a test diagnostic ECU (P/N must match and it is recommended that the controller be loaded with the latest version of the CIN). If replacing the ECU corrects the problem, reinstall the original (bad) ECU to confirm that the problem is in the ECU.
If the original ECU now works, inspect the ECU connectors for corrosion or damage which may cause an intermittent condition. If the original problem recurs, install a replacement ECU. Table 6–3. Voltage Chart Voltage Condition 33.0 (High Set Point) High Fail Limit 32.0 Maximum Continuous ECU Voltage 10.0 (Medium Low Set Point) Cannot Compensate With Sub-Modulation (Bad Shifts). Adaptive logic stops functioning 8.0 Low Voltage Fail Limit, Set Code, DNS 7.0 (Low Set Point) Software Off (ECU loses power) 4.5 Neutral Start Off