WTEC III ELECTRONIC CONTROLS TROUBLESHOOTING MANUAL DIAGNOSTIC CODES CODE 24 XX — SUMP FLUID TEMPERATURE (Figure 6–7) Table 6–6. External Hydraulic Circuit Characteristics Basic, PTO, 93˚C (200˚F) Sump Temperature MD/B 300/B 400 6–42 Copyright © 2001 General Motors Corp.
CONVERTER OPERATION MAXIMUM COOLER FLOW AT MINIMUM PRESSURE DROP LOCKUP OPERATION MAXIMUM COOLER FLOW AT MINIMUM PRESSURE DROP Input rpm Flow Pressure Drop Input rpm Flow Pressure Drop L/s gpm kPa psi L/s gpm kPa psi 600 0.10 1.6 0 0 600 0.10 1.6 0 0 800 0.23 3.7 0 0 800 0.23 3.7 0 0 1200 0.47 7.4 0 0 1200 0.50 7.9 0 0 1400 0.61 9.7 0 0 1400 0.63 10.0 0 0 1600 0.74 11.7 0 0 1600 0.77 12.2 0 0 2000 0.94 14.9 0 0 2000 0.95 15.1 0 0 2400 1.19 18.9 0 0 2400 1.12 17.8 0 0 3200 1.28 20.3 0 0 2800 1.22 19.3 0 0 3200 1.28 20.3 0 0 CONVERTER OPERATION MAXIMUM ALLOWABLE PRESSURE DROP LOCKUP OPERATION MAXIMUM ALLOWABLE PRESSURE DROP Input rpm Flow Pressure Drop Input rpm Flow Pressure Drop L/s gpm kPa psi L/s gpm kPa psi 600 0.10 1.6 10 1.5 600 0.10 1.6 5 0.7 800 0.22 3.5 40 5.8 800 0.23 3.7 46 6.7 1200 0.45 7.1 159 23.1 1200 0.48 7.6 148 21.5 1400 0.57 9.0 252 36.6 1400 0.62 9.8 247 35.8 1600 0.67 10.6 338 49.0 1600 0.73 11.6 346 50.2 2000 0.80 12.7 481 69.8 2000 0.90 14.3 561 81.4 2400 0.85 13.5 549 79.6 2400 1.07 17.0 737 106.9 3200 0.85 13.5 549 79.6 2800 1.10 17.4 770 111.7 3200 1.10 17.4 791 114.7