MAINTENANCE SERVICE PROCEDURE METHOD FOR TIGHTENING (MASTER LINK CONNECTING BOLT) 1. First tighten to a tightening torque of 343 ± 39N•m (35 ± 4kgf•m, 253 ± 29lbft) then check that the link contact surfaces are in close contact. 2. After checking the link contact surfaces, tighten the bolt by 180є (Allowable range: 0є - 20є). CHECK ELECTRICAL INTAKE AIR HEATER Before the start of the cold season (once a year), contact your Komatsu distributor to have the electrical intake air heater repaired or checked for dirt or disconnections. 4-27