MAINTENANCE SERVICE PROCEDURE CHECK OIL LEVEL IN DAMPER CASE, ADD AND CHANGE OIL G The oil is very hot just after the operation. Wait until the oil temperature drops, then start the work. G The undercover is heavy. Do not open or close it just under it. When removing bolt(2), stand after the cover so that you can escape at any moment. G When removing drain plug(5) of the damper case, take care not to get soaked with oil. If the quantity of the oil in the damper is insufficient, the damper may be seized. Accordingly, check, and add or replace the oil according to the following procedure.
G At the time of "CHANGE OIL IN POWER TRAIN CASE, CLEAN STRAINERS (POWER TRAIN STRAINER, SCAVENGING PUMP STRAINER) (PAGE 4-52)", check the oil in the damper case and add new oil, if neces- sary, and replace it at the shorter interval of two years (in every other autumn) and 2000 operating hours. INSPECTION 1. Remove the undercover from the rear bottom of the machine body according to the following procedure. 1) Remove two bolts(1) from the front side of the machine body. 2) Holding the cover, remove two bolts(2) from the rear side of the machine body. 3) Lower and open the cover gradually. Weight of undercover: 21kg (46lb) 2. Remove oil level plug(3) and check the oil level.
The proper oil level is the bottom edge of the plug hole. Tighten plug(3). REMARK G Check the oil level while the engine is stopped. G If the machine is inclined, set it in a level position before checking the oil level. 3. If the oil level is below the bottom edge of the plug hole, remove oil filler plug(4) and add new oil. Add new engine oil until the oil level reaches the bottom edge of oil level plug(3). 4. After adding the oil, tighten plugs(3) and(4). 4-37 WARNING