Komatsu — PROCEDURE FOR RELEASING INTERNAL PRESSURE OF HYDRAULIC SYSTEM

MAINTENANCE SERVICE PROCEDURE PROCEDURE FOR RELEASING INTERNAL PRESSURE OF HYDRAULIC SYSTEM G The hydraulic system is always under internal pressure, so when inspecting or replacing the piping or hoses, always release the pressure in the circuit before starting. If the pressure is not released, high pressure oil may spurt out and cause serious personal injury. G The parts and oil are at high temperature after the engine is stopped, and may cause serious burns. Wait for the temperature to go down before starting the operation. G When the oil filler cap is removed, oil may spurt out, so turn the cap slowly to release the pressure before removing the cap. 1.

Stop the machine on firm level ground. 2. Lower the blde to the ground, then stop the engine. 3. Operate the blade control lever in each direction to the stroke end to release the internal pressure within 15 sec- onds after the engine is stopped. 4. Loosen oil filler cap (F) at the top of the hydraulic tank slowly to release the internal pressure. 4-39 WARNING