2. SERVICE INFORMATION BF40AoBF50A 1. MAINTENANCE STANDARDS 2. TORQUE VALUES 3. SPECIAL TOOLS 4. APPLYING LIQUID SEALANT 5. TROUBLESHOOTING 6. CABLE 8t HARNESS ROUTING 7. TUBE ROUTING 1. MAINTENANCE STANDARDS Service limit 1 Carburetor Part Item Standard Main jet - BF4OA Bondensee type #loo - Except Bondensee type #lo5 BF50A #135 - Pilot screw opening BMOA Bondensee type 3-318 turns out - Except Bondensee type 3-112 turns out - BF50A 2-118 turns out - I Float height BF40A 14.0 mm (0.55 in) - BF50A 13.0 mm (0.51 in) - SE valve heater resistance con 15.8 - 24.2 Q - 10% min. - Exhaust emission Bondensee type only I I NOX I 546oom max. I - co Measurina idle soeed 7.0% max.
- I 1 Powercoil I Resistance I 7.02 - 8.58 Q I - 950 - 1,150 min-I (rpm) - 2. TORQUE VALUES Item Thread dia. x pitch Torque 7 1 Note N-m kgfom Engine Crankcase cover bolt M8 x 1.25 M6 x 1 .O M10 x 1.25 M8 x 1.25 M6 x 1 .O PT1/8 MlOx 1.0 27 12 39 26 13 9 65 2.8 1.2 4.0 2.7 1.3 0.9 6.6 Cylinder head bolt Oil strainer bolt Water tube joint Flywheel bolt Gear case Propeller castle nut Gear case end nut Gear case nut (UL type) M16x 1.0 M80 x 1.5 MlOx 1.25 M8 x 1.25 MlOx 1.25 M8 x 1.25 Id5 x 0.8 1 69 34 22 1.5 1.3 1 0.1 7.0 3.5 2.2 0.15 0.13 0.1 0.7 51 25 16 (4) (5) Gear case stud (UL type) I 1.1 0.9 0.7 Water screen screw 2-1