117 Maintenance Section Backup Alarm - Test SEBU7645-06 g00904205 Illustration 114 928G\IT28G g00614315 Hlustration 115 3. Turn the battery disconnect switch to the OFF Apply grease to the remote grease fittings for the trunnion bearings. The grease fittings are located on the left side of the machine near the articulation joint. position. Remove the battery disconnect switch key. i01698523 Backup Alarm - Test SMCS Code: 7406-081 Turn the engine start switch key to ON in order to perform the test. Apply the service brake. Move the transmission direction control lever to REVERSE position. The backup alarm should immediately sound.

The backup alarm will continue to sound until the transmission direction control lever is moved to the NEUTRAL position or to the FORWARD The backup alarm is mounted position. lustration 4. Remove the access panel for the battery on the right side and on the left side of the machine. in the back of the machine behind the rear grill. g00614313 116 NOTICE Do not allow the disconnected battery cable to contact the disconnect switch. 102164378 Battery or Battery Cable Inspect/Replace SMCS Code: 1401-040; 1402-040; 1402-510 1401-510; 1401-561; 1. Turn the engine start switch to the OFF position. Turn all switches to the OFF position. 2.

Open the engine access door on the right side of the machine. 5. Disconnect the negative battery cable at the battery.