Caterpillar — Caterpillar 10-140 Construction Equipment Maintenance Manual

118 Maintenance Section SEBU7645-06 Belts - Inspect/Adjust/Replace 2. Inspect the condition of the alternator belts and the adjustment of the alternator belts. The alternator belts should deflect 14 to 20 mm (0.55 to 0.79 inch) under 110 N (25 Ib) of force. Illustration 117 900614317 6. At ine battery disconnect switch, disconnect the negative battery cable that is connected to the frame. g00912370 Illustration 119 7. Perform the necessary repairs. Replace the cable or the battery, as needed. 3. Loosen mounting boit (1). Loosen adjusting 8. Connect the battery cable at the battery disconnect 4. Move the alternator until the correct tension is reached. switch, if equipped.

If the machine is not equipped with a battery disconnect switch, connect the negative cable to the frame. 9. Connect the negative battery cable at the battery. Replace the battery cover. 10. Install the battery disconnect switch key. Turn the battery disconnect switch to the ON position. 101783036 Belts - Inspect/Adjust/Replace SMCS Code: 1357-025; 1357-040; 1357-510 locknut (2). 5. Tighten adjusting locknut (2). Tighten the mounting bolt (1). 6. Recheck the belt deflection. If the amount of deflection is incorrect, repeat Step 3 to Step 5. 7. Close the engine access door. Air Conditioner Belt (If Equipped) 1. Stop the engine in order to inspect the air conditioner belt. Alternator Belt 1.

Open the engine access door on the left side of the machine. Illustration 120 900912371 2. Inspect the condition of the air conditioner belt and the adjustment of the air conditioner belt. The air conditioner belt should deflect 14 to 20 mm (0.55 to 0.79 inch) under 110 N (25 Ib) of force. INustration 118 g00912368