129 Maintenance Section Cooling System Coolant (ELC) - Change SEBU7645-06 Note: This machine is shipped with Extended Life Coolant. Extended Life Coolant is recommended for use. Drain the coolant whenever the coolant is dirty. Drain the coolant whenever the coolant starts to foam. lHustration 148 g00921568 4. The drain valve is located on the bottom left corner of the radiator. Open the drain valve. Allow the coolant to drain into a suitable container. g00928711 lilustration 146 The overflow tank is located under the access panel on the top of the engine compartment. Use the steps and the handholds in order to reach the access panel.
The steps and handholds are located on the left side of the machine. 1. Open the access panel on the top of the engine compartment. 2. Slowly lift the tab on the cap for the overflow tank in order to relieve system pressure. Remove the 5. Close the drain valve. Fill the system with a solution which consists of clean water and of cooling system cleaner. The concentration of the cooling system cleaner in the solution should be between 6 percent and 10 percent. 6. Start the engine. Run the engine for 90 minutes. Stop the engine. Drain the cleaning solution into a suitable container. 7. While the engine is stopped, flush the system with water.
Flush the system until the draining water is transparent. cap for the overflow tank. 8. Close the drain valve. 9. Add the coolant solution. See the following topics: « Operation and Maintenance Manual, “Cooling System Specifications” * Operation and Maintenance Manual, “Refill Capacities” Note: If you are using Caterpillar antifreeze, do not add the supplemental coolant additive at this time. g00921567 lllustration 147 3. Open the access doors on both sides of the engine compartment. Remove five bolts (1). Remove plate (2). 10. Start the engine. Run the engine without the cap for the overflow tank until the thermostat opens and the coolant level stabilizes.