Komatsu — 24.1 INITIAL 250 HOURS SERVICE (ONLY AFTER THE FIRST 250 HOURS)

24. SERVICE PROCEDURE 24.2.21 CHECK, MAINTAIN AIR CONDITIONER CHECK LEVEL OF REFRIGERANT (GAS) If the level of the refrigerant (gas) is low, the cooling effect will be reduced. Run the engine at high idling, and check the flow of the refriger- ant gas (freon 134a) in the refrigerant circuit through the sight glass of the receiver when the cooler is running at high speed. No bubbles in refrigerant flow: Suitable Some bubbles in flow (bubbles pass continuously): Lack of refriger- ant Colorless, transparent: No refrigerant REMARK When there are bubbles, the refrigerant gas level is low, so contact your refrigerant dealer to have refrigerant added.

If the air conditioner is run with the refrigerant gas level low, it will cause damage to the com- pressor. INSPECTION DURING OFF-SEASON Even during the off-season, run the compressor at low speed for 3 - 5 minutes once a month to prevent the loss of the oil film at the lubricated Parts of the compressor. Inspection and maintenance items list for cooler PC450-ENG 3-45 WARNING If the refrigerant used in the cooler gets into your eyes or on your hands, it may cause loss of sight or frostbite, so never loosen any part of the refrigerant circuit.

WARNING Inspection and maintenance items Contents Maintenance interval Refrigerant (gas) Filling quantity Twice a year; spring and autumn Condenser Clogging of fin Every 500 hours Compressor Function Every 4000 hours V belt Damage and tension Every 250 hours Blower motor and fan Function (Check for normal sound) When required Control mechanism Function (Check for function) When required Piping for connection Installation condition looseness of tightening connection portion gas leakage, damage When required