Komatsu — 24.1 INITIAL 250 HOURS SERVICE (ONLY AFTER THE FIRST 250 HOURS)

24. SERVICE PROCEDURE 24.2.22 CLEAN INLINE FILTER If the hydraulic system between the pump and inline filter a has been opened, or if there is any abnormality in the hydraulic equipment, remove the dirt inside the circuit as follows: 1. Remove plug b . 2. Remove and clean filter d . n When cleaning the filter, remove all dirt stuck to the side of the filter. n When reassembling the filter replace O-rings c and e with backing ring f at the same time. n After reassembling the line filter, start the engine and run at low idle for 5 minutes to bleed the air. It is not necessary to operate the control levers to bleed the air. PC450-ENG 3-46