Komatsu — 24.11.1 CHANGE OIL IN HYDRAULIC TANK

24. SERVICE PROCEDURE 6. Add the specified amount of engine oil through oil filler port F . Check that the oil level is between H and L on the sight gauge. NOTICE For details of the oil to use, see “20. USE OF FUEL, COOLANT AND LUBRICANTS ACCORDING TO AMBIENT TEMPERATURE”. NOTICE When the hydraulic breaker is installed, the hydraulic oil dete- riorates earlier than in normal bucket digging work. Therefore, re- place the hydraulic oil according to the chart at the right. 7. After replacing hydraulic oil and cleaning or replacing filter element and strainer, bleed air from the circuit according to the following pro- cedure.

Procedure for bleeding air Bleed the air from the various components in the order below (1-7). 1. Bleeding air from pump 1. Loosen air bleeding plug a , and check that oil oozes out from the air bleed plug. 2. If no oil oozes out, remove the drain hose from the pump case, and add hydraulic oil through drain port b to fill the pump case. Oil will come out when the drain hose is removed, so secure the hose mouthpiece at a position higher than the level of the oil in the hydraulic tank. 3. After completing the air bleed operation, tighten air bleeding plug a , then install the drain hose. NOTICE If the drain hose is installed first, oil will spurt out from the hole of plug a .

If the pump is operated without filling the pump case with hy- draulic oil, abnormal heat will be generated and this may lead to premature damage of the pump. 2. Starting engine Start the engine according to “12.2 STARTING THE ENGINE”. Keep running the engine at low idling for 10 minutes, and carry out the following procedure. PC450-ENG 3-76