Komatsu — 20 Testing and adjusting

TESTING AND ADJUSTING STANDARD VALUE TABLE FOR CHASSIS RELATED PARTS SM rev. PC130/150LGP-6K 20-9 Applicable model PC130-6K + PC150LGP-6K Cate- gory Item Measurement conditions Unit Standard value for new machine Service limit value Work equipment Time lag Bucket BKP00116 · Stop bucket suddenly and measure time taken for bucket to stop · Engine at low idling · Hydraulic oil temperature: 45 – 55˚C Sec Max. 2 Max. 3 Internal leakage Cylinders · Hydraulic oil temperature: 45 – 55˚C · Engine at full throttle · Relieve circuit to be measured cc/ min Max.

3.5 15 Center swivel joint 10 50 Performance in compound operation Travel deviation when work equipment + travel are operated · Engine at full throttle · Hydraulic oil temperature: 45 – 55˚C fl Use a hard horizontal surface. 20m 10m BKP00107 fl Measure dimension x. mm Max. 500 Max. 550