Cylinder Head Cylinder Head - Vacuum Testing Valve Seating for Reuse (02-10) N14 Page 2-39 Install the seal ring, Part No. 3823848, and the vacuum cup, Part No. 3823847, to the vacuum hose. NOTE: The valves and the valve seats must be clean and dry when vacuum testing. Cover the valve with the cup and the seal. NOTE: The seal must make a tight contact on the cylinder head around the valve. The seal must completely fill the two milled areas between the valves. Move the toggle switch (1) to the position. Turn the vacuum control valve (2) to the ‘‘OPEN’’ position. NOTE: The vacuum control valve is in the ‘‘OPEN’’ position if the vacuum gauge needle moves clockwise .
Operate the vacuum pump until the gauge indicates the specified vacuum. Valve to Valve Seat Vacuum mm-Hg in-Hg 5.08 MIN 20 6.35 MAX 25 Turn the toggle switch (1) to the position.