Cummins — CYLINDER HEAD - VALVES - MAGNETIC CRACK INSPECTION

Cylinder Head - Valves - Magnetic Crack Inspection (02-11) Cylinder Head N14 Page 2-40 Use a stopwatch. Start timing when the needle on the gauge indicates 457 mm-Hg [18 in.Hg]. Stop timing when the needle on the gauge indicates 203 mm Hg [8 in.Hg]. The elapsed time for the needle to move between the specified gauge readings must be 10 seconds or more. If the elapsed time is less than 10 seconds, perform the following checks: Repeat the test to make sure the equipment is op- erating correctly. Use a mallet to lightly hit the valve stem to make sure the valve is seated. Repeat the test. Apply a thin layer of grease on the outside diameters of the insert and the valve head. Repeat the test.

The grease pattern will show the point of leakage. NOTE: A break in the grease seal pattern will indicate leak- age between the valves and the valve seat or the valve seat insert and the cylinder head. Refer to Cylinder Head - Re- build (02-02). Cylinder Head - Valves - Magnetic Crack Inspection (02-11) Refer to the Alternate Repair Manual, Bulletin No. 3379035, for procedures to magnetically check for cracks in the intake and exhaust valves.