Rocker Lever Housing AssemblyRocker Lever Housing Assembly - Cleaning and Inspection for Reuse (03-05) N14 Page 3-15 Steam clean the reusable gaskets. Dry with compressed air, and check for cuts or deformations in the silicone bead. Replace the gasket if there are any cuts, abrasions, or deformations in the silicone bead. Check to see if the nylon carrier is cracked or broken; replace if necessary. NOTE: The reusable gaskets must not be cleaned with solvent. Solvent will deteriorate and swell the silicone bead and destroy the gasket. The gaskets must be cleaned with soap and water. Inspection Inspect each cover for cracks or damage, and replace if necessary.
On the cover fitted with the crankcase breather tube, inspect the breather baffle for damage. Rocker Lever Housing Assembly - Cleaning and Inspection for Reuse (03-05) NOTE: On CELECT™engines while handling the rocker lever housings, protect the wiring harness pass through connectors. Do not subject the pass through connectors to impact forces and do not rest the housing on the face with the pass through connectors. Water Manifold Tube - Removal Remove the o-ring plug and water tube from the water manifold with service tool, Part No. 3823819. Insert the jumper tube removal tool into the retainer clamp slot. Use a pry bar and pry the jumper tube out of the water manifold. Discard the o-rings.