Rocker Lever Housing AssemblyRocker Lever Housing Assembly - Cleaning and Inspection for Reuse (03-05) N14 Page 3-17 Visually inspect the pass through connectors for cracks, bent contacts, or other damage. Replace if necessary. Refer to the N14 Troubleshooting and Repair Manual CELECT™System, Bulletin No. 3810469. On STC engines, remove the oil manifold. NOTE: When removing the oil manifold connector from the rocker lever housing, use a wide flat pry bar. Pry at the center of the oil manifold. Remove the connector evenly from both of the pass through ports to prevent damage to the connector and the rocker lever housing. Clean and inspect the oil manifold.
Refer to STC Oil Plumbing - Cleaning and Inspection for Reuse (03-06). Cleaning Steam clean the rocker lever housings. Dry with compressed air. NOTE: Make sure the oil supply hole is free of dirt or other deposits. Do not remove the rocker shaft dowel pins, dowel rings, or brass cup plug for cleaning. Inspection Visually inspect the housings for cracks or damage, and replace if necessary. Visually inspect the capscrew holes for damaged threads. If threads are damaged, refer to the Alternative Repair Manual, Bulletin No. 3379035. Visually inspect the water manifold sections for cracks, pitting, corrosion, or other damage.