Cummins — INSTALLATION - LUBRICATING OIL FILTER BYPASS VALVE

Lubricating Oil Cooler Assembly - Rebuild (07-11) Lubricating Oil System N14 Page 7-38 Lubricate the o-ring with Lubriplate T 105 or equivalent, and install the shutoff valve in the filter head. Install the retaining capscrew and washer. Torque Value: 20 [15 ft-lb] Turn the valve to the position. The valve is in the ‘‘ON’’ position when the valve is in the vertical position. Install the oil cooler filter head, gasket, washers, and filter head 12 point capscrews. Torque Value:

20 [15 ft-lb] Installation - Lubricating Oil Filter Bypass Valve After lubricating all pieces and the o-ring seal, install the poppet valve (4), spring (3), the plunger (2), and retaining plug (1) into the lubricating oil cooler transfer housing (5). Tighten the retaining plug. Torque Value: 34 [25 ft-lb]