Cummins — INSPECTION

Cooling System Thermostat Housing - Cleaning and Inspection (08-05) N14 Page 8-21 Inspect the thermostat seal and the thermostat cover gasket surface for cracks, corrosion, or damage. Replace the thermostat cover if necessary. The thermostat seal can not be reused. The seal must be replaced if it is removed from the cover. Inspect the thermostat for damage. Suspend the thermostat and a 100° C [212° F] ther- mometer in a container of water. Do not allow the ther- mostat or the thermometer to touch the sides of the con- tainer. Heat the water. NOTE: Record the temperatures at which the thermostat begins to open and when it is fully open.

Allow several minutes for the thermostat to react to a stabilized water temperature. NOTE: The nominal operating temperature is stamped on the thermostat. The thermostat must begin to open within 1° C [2° F] of nominal temperature. The thermostat must be fully open to at least 9.5 mm [0.375-inch] within 12° C [22° F] above nominal temper- ature. Replace the thermostat if it does not operate as described.