Cummins — ELECTRONIC HOOKUP - CELECT ENGINES ONLY

Engine Dynamometer - Install Engine (14-01) Engine Testing N14 Page 14-14 Use an air tank (2). Install an air regulator (3) capable of maintaining 345 to 517 kPa [50 to 75 psi] air pressure at both minimum and maximum engine RPM. Install a steel tube or high temperature hose (1). Hose Temperature (Minimum): 235°C [500°F]. Connect the tube or hose (1) to the air compressor outlet. NOTE: Inspect the voltage rating on the starting motor be- fore installing the electrical wiring. Install the electrical wiring to the starting motor and bat- teries, if used. NOTE: If another method of starting the engine is used, follow the manufacturer’s instructions to make the neces- sary connections.

Electronic Hookup - CELECT™Engines Only When testing a CELECT™engine on an engine dyna- mometer, it is necessary to attach a throttle input control, and a 12 volt power supply to the ECM. A Compulink™ must also be used to bypass certain fea- tures and programmed parameters associated with the CELECT™ECM while the engine run-in or performance test is in process. The engine dynamometer OEM harness for both the N14 and L10 engines are the same. The CELECT™dyna- mometer test OEM wiring harness, Service Tool Part No. 3823948, is available through Cummins. The harness is supplied with all necessary connections and switches.

Items not supplied are the remote throttle actuator and the 12 volt battery.