General Engine Specifications (Continued) Specifications Page 18-4 NT 855 General Engine Specifications (Continued) Cooling System Metric [U.S. Customary] Coolant Capacity (engine only) ...................................................................................... 21 liters [22 U.S. qt.] Standard Modulating Thermostat Range: Conventional Aftercooling .............................................................................. 82 to 93°C [180 to 200°F] Optimized Aftercooling ...................................................................................
79 to 91°C [175 to 195°F] Maximum Coolant Cylinder Block Pressure (Pressure Cap Removed) Maximum Allowable Top Tank Temperature ........................................................................... 100°C [212°F] Closed Thermostat ............................................................................................................ 350 kPa [50 psi] Minimum Recommended Top Tank Temperature ...................................................................... 70°C [158°F] Minimum Recommended Pressure Cap ................................................................................... 50 kPa [7 psi] Exhaust System Maximum Allowable Back Pressure Created by Piping and Silencer:
Hg ..................................................................................................................................... 75 mm [3 in.] H 2 0 .............................................................................................................................. 1000 mm [40 in.] Exhaust Pipe Size (Normally Acceptable Inside Diameter) ....................................................... 127 mm [5 in.] Fuel System Note: For performance and fuel rate values, refer to the engine data sheet or the fuel pump code for the particular model involved. Maximum Allowable Restriction to Pump:
With Clean Filter ................................................................................................... 100 mm Hg [4 in. Hg] With Dirty Filter ..................................................................................................... 200 mm Hg [8 in. Hg] Maximum Allowable Return Line Restriction without Check Valves ............................. 64 mm Hg [2.5 in. Hg] Maximum Allowable Return Line Restriction with Check Valves and/or Overhead Tanks . 165 mm Hg [6.5 in.
Hg] Electrical System Minimum Recommended Battery Capacity Battery Size Ambient Temperatures -18°C (0°F) 0°C (32°F) Cold Cranking Amperes Reserve Capacity Amperes 12 Volt 1800 640 1280 480 24 Volt ** 900 320 640 240 Reserve Capacity * Amperes Cold Cranking Amperes * The number of plates within a given battery size determines reserve capacity. Reserve capacity determines the length of time sustained cranking can occur. ** CCA ratings are based on two 12-volt batteries in series.