Electronic control fuel injection system (Common rail type) 1E-97 ECM voltage Removal of ECM The ECM energizes standard voltage to various switches and sensors. The resistance value of the ECM is quite high so that the ECM can energize a voltage like this. The voltage actually applied to the circuit is low, and it does not sometimes comes on even if the test light is connected to the circuits. The voltmeter usually used in a service shop may not indicate a correct reading because the input impedance is too low. A digital multi-meter which has an input impedance of 10 M Ω (e.g. 5-8840-2691-0) should be used to get an correct reading of the voltage. 1. Turn the key switch to OFF. 2.
Disconnect the battery cable from negative terminal. 3. Remove the parts (relay etc.) around the ECM to facilitate removal of it. 4. Disconnect the ECM connector from ECM. (81-pin, 40-pin connectors) 5. Loosen the installing bolts (nuts) and remove the ECM. Note: Installation method and locations vary depending on each machine. Refer to the machine’s manual. Electrically erasable programmable read only memory (EEPROM) EEPROM has programs which is necessary for ECM to control the operation of powertrain and information for calibration. If fault is found in the EEPROM, replace the ECM. Examples of programs to control powertrain and information for calibration in ECM are the following items.
Engine model Engine number ECM part number DTC Learning value for interval correction of cylinders QR Q-key Learning value for EGR correction Installation of ECM Install the ECM in the reverse order of removal. EGR valve position learning is required after replacing the ECM. 1. Turn the key switch to “ON”. 2. Turn the key switch to “OFF”. 3. Leave as it is for 10 seconds. Failure to perform the EGR valve position learning may result in detection of DTC for EGR. About ECM power off The power supply inside the ECM does not go off for about 10 seconds after turning the key switch OFF.
If the ECM power needs to be off such as for memory clear, wait for more than 10 seconds after turning the key switch OFF. Precautions on ECM service work Note: Be sure to use the ECM with the part number corresponding to the machine. If performing welding on the machine, disconnect the battery cable from the negative terminal beforehand. Key switch ON The ECM is designed to sustain normal consumption of current relating to the operation of the machine. Circuits should not be overloaded. In case of testing of open and short circuits, the circuits of the ECM must not be connected to the ground or be supplied with voltage except that there is such an instruction.
Be sure to use a digital multi-meter (5-8840-2691-0) when performing the tests of these circuits. Key switch OFF 10 sec TSWG0176