hitachi — Scan tool power supply circuit system check

Electronic control fuel injection system (Common rail type) 1E-143 Scan tool power supply circuit system check 2 1 TSWG0162 Name 1. Battery cable 2. Power socket cable (AC/DC adapter) Circuit description The ECM and other ECUs communicate with the scan tool via data link connector (DLC). Power supply voltage for the scan tool is provided from the battery. Following inspections are necessary to detect these causes. Improper connection of harness connector and ECM connector Poor connection of terminal from connector Unmatched terminals are fitted. Damage of connector lock Poor contact between terminal and wire Damaged harness Visually check the harness for damage.

Check the relevant items on the scan tool data display while moving the connector and the harness which are related to the sensor. The variation of the display indicates the faulty part. Caution: Use a 12-V battery from the chassis ground side for the power supply to the scan tool. Diagnostic aid If the intermittent trouble is suspected, followings may be the cause. Improper connection of harness connector Defective harness routing Worn harness cladding Wire disconnection inside harness cladding Test description Important: Before starting this diagnostic step, check if the scan tool operates properly on other machine. Step Item to be checked Inspection method Measuring condition Terminal No.

Normal value Abnormal value 3 Open circuit/ high resistance Short circuit to ground Resistance measurement • Key switch “OFF” 52 - Diagnosis connector terminal 100 Ω or less 10 MΩ or more Resistance measurement • Key switch “OFF” 52 - Ground 10 MΩ or more 100 Ω or less