hitachi — Starting circuit system check

Electronic control fuel injection system (Common rail type) 1E-149 Starter safety relay control (*: Specifications (fuse current value etc.) vary depending on each machine. Refer to the machine manual.) Starter B C B Generator Battery (100A)* L (15A)* (60A)* B C Safety relay L S Glow relay 1 H-22 0.5 B/W A 1 H-1 Key switch 10 E-57 Glow relay control Engine control module (ECM) Glow plug TSWG0073 Circuit description Following inspections are necessary to detect these causes. Improper connection of harness connector and ECM connector Poor connection of terminal from connector Unmatched terminals are fitted.

Damage of connector lock Poor contact between terminal and wire Damaged harness Visually check the harness for damage. Check the relevant items on the scan tool data display while moving the connector and the harness which are related to the sensor. The variation of the display indicates the faulty part. ECM turns the starter relay “ON” when the key switch is turned to “START” position. When the starter relay is “ON”, the starter operates to start the engine. Diagnostic aid If the intermittent trouble is suspected, followings may be the cause.

Improper connection of harness connector Defective harness routing Worn harness cladding Wire disconnection inside harness cladding A B Br (ON) C (ST) OFF ON START B ACC Br (ON) C (ST) OFF ON START