1E-154 Electronic control fuel injection system (Common rail type) Starting system check (*: Specifications (fuse current value etc.) vary depending on each machine. Refer to the machine manual.) 5 (15A)* Main relay H-6 0.75 R/L E-162 1 1 E-161 PCV2 PCV1 2 E-162 2 E-161 0.75 R/W 0.75 R/B 2 1 H-6 H-6 97 E-56 89 E-56 105 E-56 113 E-56 Engine control module (ECM) TSWG0077 About starting system check Diagnostic aid Starting system check is systematic method to detect the cause of that engine does not start. Followings are the preconditions for performing this diagnosis. Battery is fully charged, and battery cable is securely connected. Engine speed at cranking is normal.
Sufficient amount of fuel is supplied. No air mixed in the fuel. Air cleaner element and fuel filter is normal. Correct fuel is used. If there is relevant DTC to CKP sensor and G sensor, the engine will not start until memory clear is performed. If the intermittent trouble is suspected, followings may be the cause. Improper connection of harness connector Defective harness routing Worn harness cladding Wire disconnection inside harness cladding Following inspections are necessary to detect these causes. Improper connection of harness connector and ECM connector Poor connection of terminal from connector Unmatched terminals are fitted. Damage of connector lock Important:
Start with the DTC diagnosis relevant to fuel system if there is any.