hitachi — QOS system check

1E-166 Electronic control fuel injection system (Common rail type) (15A)* A A Machine trouble diagnosis monitor Meter Tachometer Diagnosis lamp Engine oil pressure lamp QOS indicator lamp Boost temperature lamp Machine control unit CAN HIGH CAN LOW 37 E-57 18 E-57 6 E-57 8 E-57 17 E-57 11 E-57 7 E-57 Engine control module (ECM) Diagnosis lamp control Engine oil pressure lamp control QOS indicator lamp control Boost temperature lamp control Tachometer signal CAN HIGH CAN LOW Note: The QOS circuit is the same for both the starter ECM control specifications and the safety relay specifications. Test description TSWG0075 Numbers below indicate step numbers in the chart. 7.

The QOS indicator lamp turns on when the key switch is “ON” using lamp check function, even if the QOS is not operating. 12. The QOS indicator lamp goes off within maximum 10 seconds. Circuit description The QOS (Quick On Start) system consists of the ECM, glow relay, glow plug, and QOS indicator lamp. When the key switch is turned ON with low engine coolant temperatures, the ECM determines the glow time and operates the glow relay and QOS indicator lamp. After a certain time has elapsed, the ECM will turn the glow relay and QOS indicator lamp to “OFF”. Step Action Value YES NO 1 Perform the OBD check. Is the procedure completed? — Go to Step 2. Go to “OBD system check”.