hitachi — List of diagnostic trouble code

1E-170 Electronic control fuel injection system (Common rail type) List of diagnostic trouble code List of diagnostic trouble codes On some machines, the diagnosis lamp comes on instead of trouble display monitor on the machine. DTC Flash code DTC description Item to be detected Preconditions when DTC is set DTC set condition Judgment Time Behavior when trouble occurs Diagnos is lamp Recovery from failure P0088 118 Common rail pressure fault (1st stage) Common rail pressure abnormal increase • Key switch input voltage is 16V or more. • DTC P0088, P0192, P0193, or P1635 is not detected. • Actual rail pressure is 2 MPa (290 psi) or more, and 70 rpm or more.

Rail pressure is more than 150 MPa (21756 psi). Approx. 5 sec. Intense engine vibration, rough idling, output lowering, blow up fault, black smoke emitted, and excessive output are possible. Back-up: Limited injection amount 3 (multi-injection stopped) target RP upper limit (80 MPa {11603 psi}) ON *1 Common rail pressure fault (2nd stage) Common rail pressure abnormal increase • Key switch input voltage is 16V or more. • DTC P0088, P0192, P0193, or P1635 is not detected. • Actual rail pressure is 2 MPa (290 psi) or more, and 70 rpm or more. Common rail pressure fault (1st stage) is completed, and rail pressure is more than 155 MPa (22481 psi). Approx. 5 sec.

Intense engine vibration, rough idling, output lowering, blow up fault, black smoke emitted, and excessive output are possible. Back-up: Limited injection amount 3 (multi-injection stopped) target RP upper limit (80 MPa {11603 psi}) ON *1 P0089 151 Common rail pressure fault (Excessive pressure feed in the pump) • Key switch input voltage is 16V or more. • DTC P0089, P0192, P0193, or P1635 is not detected. • Coolant temperature is 60°C (140°F) or more, and 375 rpm or more. Actual rail pressure higher than target rail pressure for 10 MPa (1450 psi) or more holds 8 seconds or more.

Or actual rail pressure higher than target rail pressure for 10 MPa (1450 psi) or more holds 8 seconds or more, during indication of no pressure feed. Approx. 8 sec. Intense engine vibration, rough idling, output lowering, blow up fault, black smoke emitted, and excessive output are possible. Back-up: Limited injection amount 3 (multi-injection stopped) target RP upper limit (80 MPa {11603 psi}) ON *1 P0091 247 PCV1 open circuit or ground short PCV1 electrical wiring open circuit/ ground short • Main relay power supply voltage is 16V or more. • DTC P0092 is not detected. • 300 rpm or more, or actual rail pressure exceeds target rail pressure PCV1 monitor signal is fixed to Low-side. Approx.

1 sec. Intensive engine vibration, rough idling, output lowering, blow up fault, black smoke emitted Back-up: Limited injection amount 3 (multi-injection stopped) target RP upper limit (80 MPa {11603 psi}) ON *2