hitachi — QOS system check

Electronic control fuel injection system (Common rail type) 1E-169 Step Action Value YES NO 19 Repair the power supply circuit between the glow relay and the glow plug, or the short circuit to the ignition power supply circuit. Is the procedure completed? — Go to Step 21. — 20 Replace the glow plug. Is the procedure completed? — Go to Step 21. — 21 1. Turn the glow relay “ON” using the “Glow plug test” of the scan tool. When the scan tool is not available, remove the glow relay and short between the terminals. 2. Measure the voltage between each cylinder glow plug harness terminal and the ground using DMM. Are the voltages at all the cylinders more than specified value? 18V Go to Step 22.

Go to Step 16. 22 1. Turn the glow relay “OFF” using the “Glow plug test” of the scan tool. When the scan tool is not available, remove the glow relay. 2. Measure the voltage between each cylinder glow plug harness terminal and the ground using DMM. Are the voltages at all the cylinders specified value? 0V Verify repair. Go to Step 17.