1E-168 Electronic control fuel injection system (Common rail type) Step Action Value YES NO 12 1. Turn the key switch to “OFF”. 2. Turn the key switch to “ON”. 3. Check the QOS indicator lamp. Does the QOS indicator lamp go OFF within 10 seconds? — Go to Step 14. Go to Step 13. 13 1. Check the version of ECM software. 2. Rewrite the software if version upgraded is necessary. If rewriting is not necessary, go to step 3. 3. Replace the ECM. Refer to “How to use flash tool” in this section for check and rewriting of ECM. Is the procedure completed? — Go to Step 14. — 14 1. Perform “Glow plug relay” test using scan tool.
When the scan tool is not available, remove the relay and test it by itself. 2. Press the “ON” and “OFF” softkeys. Does the glow relay display (contact) “ON” and “OFF”? — Go to Step 15. Go to Step 13. 15 1. Turn the key switch to “OFF”. 2. Remove all the glow plugs. 3. Measure the resistance between each glow plug terminal and the ground. Is the resistance specified value? 6Ω (Normal temperature) Go to Step 16. Go to Step 20. 16 1. Turn the glow relay “ON” using the “Glow plug relay” test of the scan tool. When the scan tool is not available, remove the glow relay and short between the terminals. 2.
Measure the voltage between each cylinder glow plug harness terminal and the ground using DMM. Are the voltages at all the cylinders more than specified value? 18V Go to Step 17. Go to Step 18. 17 1. Turn the glow relay “OFF” using the “Glow plug test” of the scan tool. When the scan tool is not available, remove the glow relay. 2. Measure the voltage between each cylinder glow plug harness terminal and the ground using DMM. Are the voltages at all the cylinders specified value? 0V Normal system Go to Step 19. 18 Repair the open circuit between the glow relay and the glow plug, or the short circuit to the ground circuit. Is the procedure completed? — Go to Step 21. —