Electronic control fuel injection system (Common rail type) 1E-175 DTC Flash code DTC description Item to be detected Preconditions when DTC is set DTC set condition Judgment Time Behavior when trouble occurs Diagnos is lamp Recovery from failure P0340 14 G sensor fault (no signal) Open circuit in sensor/ wiring • Key switch input voltage is 16V or more. • Crank pulse is normal. • DTC P0335, P0336, P0340, P0341, P1345, or P1635 is not detected. • Engine is running. Crank signal exists but no G sensor signal. When trouble occurs 7 out of 8 samples. Behavior does not change during engine running. After engine stalls, engine will not start. Back-up:
Engine running based on crank when it is normal After engine stops: Unable to identify cylinder (unable to restart) ON *1 P0341 G sensor fault (signal fault) Broken teeth/ unnecessary signal mixed (such as short circuit with other wiring) • Key switch input voltage is 16V or more. • Crank pulse is normal. • DTC P0335, P0336, P0340, P0341, P1345, or P1635 is not detected. • Engine is running. Number of pulse for G sensor signal is mismatched. When trouble occurs 7 out of 8 samples. Behavior does not change during engine running. After engine stalls, engine will not start. Back-up: Engine running based on crank when it is normal After engine stops:
Unable to identify cylinder (unable to restart) ON *1 P0380 66 Glow relay fault Open/short circuit/ damage of relay or harness • Key switch input power supply voltage is higher than 16 V but lower than 32 V. Glow relay drive indication signal is unmatched with glow relay monitor signal. When trouble occurs 25 out of 30 samples. Operationality is not affected. Startability deteriorates at low temperatures. Back-up: No back- up ON *1 P0381 67 Glow lamp fault Open/short circuit/ damage of lamp or harness • Key switch input voltage is 16V or more. • DTC P0381 is not detected. Glow lamp drive indication signal is unmatched with glow lamp monitor signal. When trouble occurs 25 out of 30 samples.
Operationality is not affected. Back-up: No back- up ON P0487 44 EGR position sensor fault (Brushless specification ) Open/short circuit/ damage of sensor harness • Main relay input voltage is 16V or more. • DTC P1630 or P1635 is not detected. EGR position output signal is abnormal. Approx. 3 sec. Operationality is not affected. Back-up: Instruction to fully close EGR valve ON *2 P0488 45 EGR valve control fault Trouble/ open circuit or valve engage/ stuck in drive motor side • DTC P1630, P1635, P0487, or P0488 is not detected. • Main relay voltage is between 20 — 32 V. • Difference between target EGR opening angle and actual one is 20% or less.
EGR drive duty is 90% or more, and difference between target valve lift and actual position is more than 20%. Approx. 10 sec. Operationality is not affected. Back-up: Instruction to fully close EGR valve ON *1