hitachi — List of diagnostic trouble code

1E-176 Electronic control fuel injection system (Common rail type) DTC Flash code DTC description Item to be detected Preconditions when DTC is set DTC set condition Judgment Time Behavior when trouble occurs Diagnos is lamp Recovery from failure P0522 294 Engine oil pressure sensor fault (low voltage fault) Open/short circuit/ breakage of sensor or harness • Key switch input voltage is 16V or more. • DTC P1633 is not detected. Engine oil pressure sensor voltage is less than 0.1 V. Approx. 4 sec. Operationality is not affected. Back-up: No back- up ON *2 P0523 Engine oil pressure sensor fault (high voltage fault) Short circuit in sensor or harness • Key switch input voltage is 16V or more.

• DTC P1633 is not detected. Engine oil pressure sensor voltage is more than 4.85 V. Approx. 4 sec. Operationality is not affected. Back-up: No back- up ON *2 P0601 53 ROM fault ROM fault — ROM is faulty. Reflash failure — Engine stopped Back-up: Engine stopped ON P0603 54 EEPROM fault EEPROM fault — EEPROM is faulty. — Operationality is not affected. Back-up: No back- up ON *2 P0606 51 CPU fault CPU fault — Sub-CPU detects main CPU fault in 100 msec after key switch ON. (SUB-CPU resets CPU.) Nearly simultaneo us to fault occurrence Output lowering Back-up:

Specified back-up value SUB-CPU stops control ON *2 52 CPU monitoring IC fault Sub-CPU fault • 480 msec or more has elapsed after key switch ON. • Key switch input power supply voltage is higher than 16 V. RUN-SUB pulse does not change for 20 msec or more. Nearly simultaneo us to fault occurrence Output lowering Back-up: Limited injection amount 1 ON *2 P0611 34 Charge circuit fault (bank 1) ECM charge circuit 1 fault (internal burnout, open circuit, etc.) • Main relay power supply voltage is 16V or more. When charge circuit bank 1 voltage inside ECM is low. Approx. 1.5 sec. Intensive engine vibration, rough idling, output lowering, blow up fault, engine stall are possible. Back-up:

Specified back-up value ON *2 P0612 Charge circuit fault (bank 2) ECM charge circuit 2 fault (internal burnout, open circuit, etc.) When charge circuit bank 2 voltage inside ECM is low. Approx. 1.5 sec. Intensive engine vibration, rough idling, output lowering, blow up fault, engine stall are possible. Back-up: Specified back-up value ON *2 P0615 19 Starter cut relay fault Relay fault • Key switch input power supply voltage is between 16 — 32 V. No starter cut relay monitor signal exists against starter cut relay drive signal. When trouble occurs 40 out of 50 samples. Operationality is not affected. Back-up:

No back- up ON *1 P0650 77 Check engine lamp fault Lamp fault • Key switch input voltage is 16V or more. • DTC P0650 is not detected. No check engine lamp monitor signal exists. When trouble occurs 11 out of 12 samples. Operationality is not affected. Back-up: No back- up ON *1