Electronic control fuel injection system (Common rail type) 1E-197 About PCV Breaker box inspection procedure Perform the inspection in the following procedure if there is such an instruction to use breaker box in the step. After inspection, return to the diagnostic step. 1 2 TSWG0010 Name 1. PCV #1 2. PCV #2 Name 1. Breaker box 2. DMM Name 1. PCV-HI 2. PCV-LO Step Item to be checked Inspection method Measuring condition Terminal No. Normal value Abnormal value 4 Open circuit/ high resistance Resistance measurement • Remove the PCV connector.
• Key switch “OFF” 105 - PCV terminal 113 - PCV terminal 89 - PCV terminal 97 - PCV terminal 5 Ω or less 10 MΩ or more Short circuit to ground Resistance measurement • Remove the PCV connector. • Key switch “OFF” 105 - Ground 113 - Ground 89 - Ground 97 - Ground 10 MΩ or more 100 Ω or less