hitachi — DTC: P0091/P1291 (Flash code 247/248) PCV circuit fault (PCV1 open circuit or GND short circuit / PCV2 open circuit or GND short circuit)

1E-198 Electronic control fuel injection system (Common rail type) On-board check procedure for sensors 3 1 2 4 TSWG0197 Name 1. Coupling connector between engine — the machine 2. Machine harness 3. Sensor connector 4. Engine harness 1. Disconnect the coupling connector, and check the sensor from engine harness connector. 2. Disconnect the connector from sensor, and short the wiring of sensor connector. 3. Check the harness from coupling connector for open circuit. If both steps 1 and 2 are faulty, repair the harness. Check from step 1 again. If only step 1 is faulty, replace the sensor. Step Item to be checked Inspection method Measuring condition Terminal No.

Normal value Abnormal value 5 Short circuit between terminals Resistance measurement • Remove the PCV connector. • Key switch “OFF” 105 - 89 105 - 97 113 - 89 113 - 97 10 MΩ or more 100 Ω or less Short circuit to power supply circuit Voltage measurement • Remove the PCV connector. • Key switch “ON” 105 - Ground 113 - Ground 89 - Ground 97 - Ground 0V 18V or more Short circuit to other signal circuit Voltage measurement • Remove the PCV connector. • Key switch “ON” 105 - Ground 113 - Ground 89 - Ground 97 - Ground 0V 1V or more